Ingress Protection / Environmental Testing


Ingress Protection

Specific Tests Or Types Of Tests Performed Specification, Standard (Method) Or Technique Used Range Of Testing/ Limit Of Detection
Electrical equipments and enclosures IS/IEC 60529 : 2001 , IEC 60529:2013, IS 12063 and equivalent IP 1X to 6 X and X 1 to X 8
Rotating Machines IS/IEC 60034 -5:2000, IEC 60034-5:2006 and IS 4691 and equivalent IP 1X to 6 X and X 1 to X 8
Luminaries IS 10322 Part 4 and equivalent IP 5X to 6 X and X 1 to X 8
Low voltage switchgear and control gear IS/IEC 60947: 2007 Part 1 Appendix C and equivalent IP 1X to 6 X and X 1 to X 8
SCOPE FOR SITE WORK
Electrical equipments and enclosures IS/IEC 60529 : 2001 , IEC 60529:2013, IS 12063 and equivalent IP 1X to 4 X and X 3 to X 6
Rotating Machines IS/IEC 60034 -5:2000, IEC 60034-5:2006 and IS 4691 IP 1X to 4 X and X 3 to X 6
Luminaries IS 10322 Part 4 X 3 to X 6
Low voltage switchgear and control gear IS/IEC 60947: 2007 Part 1 Appendix C IP 1X to 4 X and X 3 to X 6

Environmental Testing (Cold / Dry Heat / Damp Heat, Steady State and Cyclic/ Salt Mist)

Specific Tests Or Types Of Tests Performed Specification, Standard (Method) Or Technique Used
Cold ( Low Temperature) IS 9000 (Part II Sec 1 to 4 ,
IEC 60068-2-1 and Similar
Dry Heat
(High temperature )
IS 9000 Part III Sec 1 to 5,
IEC 60068-2-2 and Similar
Change of Temperature IS 9000: (Part 14)
IEC 60068-2-14
Damp Heat
steady state
IS 9000 Part IV,
IEC 60068-2-78 and Similar
Damp Heat
Cyclic
IS 9000 Part V,
IEC 60068-2-30 and Similar
Composite Temperature and Humidity Test IS 9000 Part VI and Similar
Salt Spray
(Corrosion )
IS 9000 Part XI, IEC 60068-2-11 and Similar
Temperature cycling
Test
IS 9000 Part XXIV and Similar

IK Testing

Untitled

Our Accreditation / Recognitions

PESO

DGMS

IECEx

NABL

BIS

DGFASLI

News & Events

  • February – 2017

    KLPL conduits specialized training workshop for DGMS officers.
    Read More



  • August – 2016

    IECEx Training & Competency Programs: Sets off in flying colors.

    Read More



  • February – 2016

    DGMS visits Karandikar Laboratories.
    Read More



  • May – 2015

    Karandikar Laboratories Pvt Ltd is an accepted IEC Ex Testing Laboratory
    Read More



Contact Us

Head Office:

B-101, Ansa Industrial Estate,
Saki Vihar Road, Saki Naka,
Andheri (E), Mumbai - 400 072